Multiple Chambers
for Long-Term, Unattended Measurements
The LI-8150 Multiplexer greatly expands the capability of the
LI-8100 and provides a simple solution that satisfies both temporal and spatial
resolution requirements for monitoring CO
2 flux.
Designed exclusively for use with the LI-8100, the LI-8150 allows up to 16
chambers to be connected to provide adequate spatial coverage. The system's
automation enables long-term, unattended measurement of diel and seasonal
flux patterns.
-
Connect up
to 16 Long-Term Chambers
-
30 m (98.4
ft) diameter coverage
-
Easy connection
to the LI-8100 Analyzer Control Unit (ACU)
-
Single gas
analyzer in the LI-8100 prevents measurement bias
-
Conduct
vertical atmospheric CO2 profile
measurements
LI-8150
Demonstration video
Managing Spatial
and Temporal Variability
Because of the inherent variability of soils, conducting measurements at
multiple locations is often necessary to obtain a reliable mean soil CO
2 flux
value. For example, a relatively uniform site with a coefficient of variation
(CV) of 10% may require approximately 15 flux measurements at different locations
to obtain a mean value with a measurement uncertainty of about 5%.
In addition to spatial heterogeneity, soils also exhibit both diel and seasonal
patterns of variation in CO
2 evolution
due to changes in soil water content, temperature, carbon resources, and other
factors. To accurately obtain site CO
2 fluxes,
measurements with sufficient temporal and spatial resolution are required.
Modular Construction
The LI-8150 easily connects to the LI-8100 Analyzer Control Unit and allows the researcher to choose an optimum number
of chambers with the flexibility of adding more chambers as needed. An 8-port LI-8150 can take up to 8 chambers and
can easily be upgraded to 16 ports for 8-16 chambers with a factory upgrade or field upgrade kit. Critical design
features ensure measurement accuracy regardless of how many chambers are used.
Inside the LI-8150
The interior design of the LI-8150 Multiplexer features high quality, robust components for optimal performance and in-field serviceability:
- Durable, gasket sealed weatherproof case.
- Turck® weatherproof fittings for chamber electrical connections.
- O-ring sealed, quick-attach sample air line connectors.
- High flow, low power, long-life solenoid valves.
- LED indicator panel displays diagnostic information.
- Chamber actuator button closes all chambers for transport.
- Rotary vane pump samples air streams with minimal pulsations.
- Filter assemblies clean incoming air.
Inside view of a 16 port LI-8150 with labeled components.
Multiplexed long-term system with LI-8150 Multiplexer (left), LI-8100 Analyzer Control Unit (right), and long-term chambers (background)
Four chamber system with 8100-104 Long-Term Chambers
Eight chamber multiplexed system
8150-770 AC Power Supply
DC or AC Power
In a multiplexed system, DC power is supplied to the LI-8100 and LI-8150 via the LI-8150's power input terminal.
LI-COR provides an optional 3 m DC cable with bare wire leads for connecting to a 10.5-14.5 VDC battery.
AC power can also be used with an optional AC Power Supply (8150-770). The AC Power Supply provides a
constant 12 VDC power source (4.5A maximum) and is designed for long-term outdoor deployment.

Atmospheric CO2 Profiling

In a multiplexed system, atmospheric CO
2 profile measurements can be performed, in addition to
soil CO
2 flux measurements, with minimal added cost. Available
Multiplexer ports (not occupied by chambers) can be used for this application. An atmospheric
profiling kit is available (Part #8150-662) for use with the multiplexed LI-8100 System.
View document