prev

LI-8100 System Ordering Information

The tabs below provide a useful way to view components and parts and accessories for different system configurations, depending on your needs and requirements. Use the system guide open in the first tab to quicky view required, recommended, and optional components for survey, long-term, and multiplexed systems. Use the parts and accessories tabs to view specific part numbers and descriptions for each available part or accessory.

Download a complete LI-COR Environmental Products Catalog here.

For pricing and delivery time, please contact LI-COR or your local Distributor.

LI-8100 System ordering information
Part Number Description
LI-8100 Includes Analyzer Control Unit, Auxiliary Sensor Interface, Serial Cable Interface, RS-232 Serial Cable, RS-232 to USB Adapter, Spares Kit, Compact Flash Memory Card, PC Card Adapter, Shoulder Strap Kit, Software CD (Windows® and Palm® Interface plus Data Analysis Software) and Instruction Manual (Chamber, Battery and Battery Charger not Included)
 
LI-8100 requires one or more of the following chambers:
8100-101 Long-Term Chamber
Includes gasket kit, spares kit and two soil collars
8100-102 Survey Chamber, 10 cm
Includes 8100-201 soil temperature probe, gasket kit, spares kit and six soil collars
8100-103 Survey Chamber, 20 cm
Includes 8100-201 soil temperature probe, gasket kit, spares kit and six soil collars
8100-104 Long-Term Chamber
Includes gasket kit, spares kit and two soil collars

PDA Requirements:

With serial cable: PDA running Palm OS 3.51 or higher.

Wireless: PDA running Palm OS 4.1 or higher, and supporting 802.11b wireless connectivity.

 
Multiplexed LI-8100: Special Pricing Packages:
LI-8100-M1 Four Chamber Multiplexed Package
Includes LI-8100 Analyzer Control Unit, LI-8150-8 Multiplexer, four 8100-104 Long-Term Chambers and four 8150-705 Cable/Hose Assemblies. Requires AC or DC power (not included). Auxiliary sensors sold separately.
LI-8100-M2 Four Chamber Multiplexed Package
Includes LI-8100 Analyzer Control Unit, LI-8150-16 Multiplexer, four 8100-104 Long-Term Chambers and four 8150-705 Cable/Hose Assemblies. Requires AC or DC power (not included). Auxiliary sensors sold separately.
Discounts available for additional long-term chambers, contact LI-COR or your distributor.
 
LI-8100 Accessories
6400-03 Rechargeable Battery
For use in survey applications. Provides 3 or more hours of battery life.
LI-6020 Battery Charger (92-138/184-276 VAC, 47 to 63 Hz)
8100-201 Soil Temperature Probe (Omega®)
Type E, -40 to >100°C
8100-203 Soil Temperature Thermistor
8100-202 Soil Moisture probe (ECH2O®)
Volumetric water content, 0 to saturation
8100-204 Soil Moisture Probe (Theta)
ThetaProbe Soil Moisture Sensor - ML2x
8100-554 Compact Flash Memory Card
Industrial grade, 1 GB, Type 1
8100-561 Wireless Communications Package
Includes Palm® PDA, Serial Cable for the PDA, Cisco® Wireless Card (802.11b), and Palm® Universal Travel Kit. (Wireless communication may not work in all locations or at all times due to local interferences. For this reason, a serial cable backup is included.)
8100-664 Trace Gas Sampling Kit. Used to collect samples from the same air stream used to measure CO2 flux for further trace gas analysis.
8100-704 Cable/Hose Assembly (2 m). Used to connect the 8100-104 Long-Term Chamber to the LI-8100 Analyzer Control Unit.
6581-044 8100-101 or 8100-103 Soil Collar (20 cm)
6581-157 8100-102 Soil Collar (10 cm)
6400-27 Serial to USB adapter
 
Part Number Description
LI-8150 Multiplexer
LI-8150-8 8-Port Multiplexer
Connect up to eight 8100-101 Long-Term Chambers or gas sampling lines. Includes Spares Kit and Cable/Hose Assembly for connection to LI-8100 Analyzer Control Unit. LI-8100, Chambers, and Power Supply not included. (Note: LI-8150 powers the LI-8100 Analyzer Control Unit when connected.)
LI-8150-16 16-Port Multiplexer
Connect up to sixteen 8100-101 Long-Term Chambers or gas sampling lines. Includes Spares Kit and Cable/Hose Assembly for connection to LI-8100 Analyzer Control Unit. LI-8100, Chambers, and Power Supply not included. (Note: LI-8150 powers the LI-8100 Analyzer Control Unit when connected.)
LI-8150 Accessories
8150-706 DC Power Cable
3 m cable, bare leads termination. For user-supplied DC power source.
8150-770 AC Power Supply
Includes connection to LI-8150.
8150-661 Chamber Interface Box
Required for every multiplexed 8100-101 Long-Term Chamber where auxiliary sensors are to be connected.
Allows for connection of up to three auxiliary sensors.
8150-662 Profiling Kit. Used for performing atmospheric profiling studies using the LI-8150 Multiplexer and LI-8100 Analyzer Control Unit. Call LI-COR for details.
8150-705 Cable/Hose Extension Assembly
15 meters in length. Use only one extension per chamber.
8150-202 Soil Moisture Probe (ECH2O®)
Volumetric water content, 0 to saturation
8150-204 Soil Moisture Probe (Theta)
ThetaProbe Soil Moisture Sensor - ML2x
8150-203 Soil Temperature Thermistor
For use with multiplexed 8100-101 Long-Term Chambers.
8150-916 16 Port Upgrade
Upgrade an eight-port Multiplexer to sixteen ports. Includes factory installation.
8150-916-1 16 Port Field Upgrade Kit
Field installation kit includes control panel assembly, solenoid/valve bank assemblies, Multiplexer module PCA boards, filter assemblies, necessary hardware, and instruction document.
392-08577 Sensor Connection Cable. Used to connect user-supplied sensors directly to the 8100-104 Long-Term Chamber when multiplexing or 8150-661 Chamber Sensor Interface.
 
Part Number Description
LI-8100 Analyzer Control Unit
122-02796 Screw - holds air manifold together
122-03280 Screw - secures white panel to yellow case
192-00226 O-ring that seals optical bench to source, detector blocks
192-02597 O-ring, inside brass manifold
222-01824 Bev-A-Line Plastic Tubing
300-01961 Balston disposable air filter
300-03123 Quick Connect Straight Union, 1/4"
300-03125 Quick Connect Right Angle, 1/4"
300-03367 Quick Connect Union "Y", 1/4"
300-07124 Quick Connect Plug 0.165 Barb
300-07125 Quick Connect Coupler 0.165 Barb
439-04215 3 Amp Fast Blow Fuse 250V 5X20 mm   
610-05314 Wrapped point cleaning tip 3" (for cleaning optical bench)
610-05315 Sock tip cleaning swab (for cleaning optical bench)
 
8100-101 Long Term Chamber
122-00009 Screw:   A) attaches chamber spacer and spacer clamp ring to bowl, B) attaches bowl assembly to chamber shield, C) attaches cable clamps to chamber shield, D) attaches pc board cover
122-00016 Screw:   mounts motor assembly to drive arm
122-01578 Screw:   secures gasket and clamp ring to base plate
122-07715 Screw:   attaches leg assembly to base plate
165-00140 Thumb Nut - top of vent
6581-044 20 cm Soil Collar
8100-612 8100-101 Gasket Kit:  Includes 6 ft.of black lip material around bottom of bowl, 2 collar gaskets (with screw holes), spare hardware, Loctite adhesive.
 
8100-102 Survey Chamber, 10 cm
122-00014 Screw:   A) attaches manifold to chamber can,   B) attaches bellows and clamp plates to manifold block
122-01578 Screw:   attaches rubber gasket and support ring to bottom flange
122-04328 Screw:   A) attaches frame members to bottom flange,   B) attaches seal ring to bottom flange,   C) mounts top plate to frame
165-00140 Thumb Nut - top of vent  
167-07255 Washer:   between manifold and chamber can
6560-228 10 cm Soil Collar
8100-622 10 cm Survey Chamber Gasket Kit;   Includes 2 manifold gaskets, 2 collar gaskets (with screw holes), 2 flange gaskets, 20 soil collar foam seals, 2.2 ft. of black lip material around bottom of bowl, spare hardware, Loctite adhesive.
8100-623 Bellows Replacement Kit; Includes one replacement neoprene bellows, a manifold gasket, lubricant, and necessary hardware.
 
8100-103 Survey Chamber, 20 cm
122-00014 Screw:   A) attaches manifold to chamber bowl,   B) attaches bellows and clamp plates to manifold block
158-07847 Screw:   attaches gasket clamp ring to adapter flange
163-02618 Hex Cap Nut:   secures chamber frame to adapter flange
165-00140 Thumb Nut - top of vent  
167-00154 Washer:   between chamber frame and adapter flange
167-07255 Washer:   between manifold and chamber bowl
6581-044 20 cm Soil Collar
8100-623 Bellows Replacement Kit; Includes one replacement neoprene bellows, a manifold gasket, lubricant, and necessary hardware.
8100-632 20 cm Survey Chamber Gasket Kit;   Includes 2 manifold gaskets, 4 collar gaskets (with screw holes), 20 soil collar foam seals, 6 ft. of black seal material around bottom of bowl, spare hardware, Loctite adhesive.
 
8100-104 Long Term Chamber
165-00140 Thumb Nut - top of vent
6581-044 20 cm Soil Collar
191-08069 Bumper
222-00303 Urethane Tubing 1/8" ID, 1/4" OD
218-08499 Cable Tie
620-08297 Vinyl Cap Plug
8100-612 8100-101 Gasket Kit:  Includes 6 ft.of black lip material around bottom of bowl, 2 collar gaskets (with screw holes), spare hardware, Loctite adhesive.
 
LI-8150 Multiplexer
222-00303 Urethane Tubing
300-02627 PVDF Hose Barb T-Fitting
300-08151 Quick Connect Plug
300-08249 Solenoid Valve (Individual)
439-04214 Multiplexer Box Fuse
610-08324 Sensor Box Strain Relief Plug
620-08298 Vinyl Cap for Quick Connect Plug
620-08299 Vinyl Cap for Quick Connect Coupler
9981-091 Multiplexer Pump Assembly
9981-123 Multiplexer Filter Assembly


 

prev
x
A A A
line
800 | 1024 | max
Biotechnology
4647 Superior St
Lincoln, NE 68504
Toll-Free: 800-645-4267
Email: biohelp@licor.com
Environmental
4421 Superior Street
Lincoln, NE 68504
Toll-Free: 800-447-3576
Email: envsales@licor.com