LI-8100TR Automated Soil CO2 Flux and Atmospheric Monitoring System - Teaching & Research Package
Available in the United States, Puerto Rico, and Canada
Why the LI-8100TR Package
The college classroom and field laboratory provide the bridge for today's students to become tomorrow's researchers. The rapidly accelerating study of environmental climate change offers a new generation of scientists unprecedented challenges and opportunities. In order to be properly trained, students need to gain experience in CO2 measurement theory, practical application, and instrumentation. The LI-8100TR provides educators and researchers sophisticated CO2 monitoring instrumentation in a dedicated system that is integrated and easy to use. It accurately measures soil CO2 flux as well as vertical atmospheric CO2 profiles. The LI-8100TR is the complete teaching and research package at a great savings.
Benefits for Teaching
The LI-8100TR is a perfect fit for educational and research based instruction, offering complete instrumentation for a variety of applications. The LI-8100TR includes a field guide on CD with prepared field exercises, and includes instrumentation for educators to quickly implement a variety of systems for incorporation into their curricula.
- Soil CO2 Flux Measurements – Spatial or Temporal Measurements or both
- Survey measurements – spatial variability of soil CO2 flux. Cover a large area in a short period of time
- Long-term, single chamber measurements – temporal variability of soil CO2 flux
- Multiplexed, four chamber measurements – spatial and temporal variability of soil CO2 flux
- Measure soil temperature and moisture with included sensors
- Measure other parameters, such as wind speed and direction (use-supplied sensors)
- Vertical atmospheric profile CO2 studies as well as horizontal atmospheric CO2 measurements
- Profiling kit is included
- Measure up to four different heights
- Measure along four horizontal locations
- No additional cost
- Sample chamber air for analysis of additional trace gases flux across the soil surface (i.e. CH4, N2O etc)
- Trace gas sampling kit is included
- Further analysis is required using chromatography or other analytical methods
| Product Model |
Number Included |
Product Name |
Notes |
| LI-8100 |
1 |
Analyzer Control Unit |
The gas analysis, communications center, data storage center, and power center. Can also connect auxiliary sensors directly. |
| LI-8150-8 |
1 |
Multiplexer, 8-port |
Connect up to 8 long-term chambers and/or use it for atmospheric profiling. |
| 8100-103 |
1 |
Survey Chamber, 20 cm |
Connect directly to the LI-8100 for fast and repeatable survey measurements. |
| 8100-104 |
4 |
Long-Term Chamber |
Connect directly to the LI-8100 for single chamber long-term measurements or connect to the LI-8150-8 to multiplex. |
| 8150-705 |
4 |
Cable/Hose Assembly, 15 m |
For connecting the 8100-104 to the LI-8150-8. |
| 8150-704 |
1 |
Cable/Hose Assembly, 2 m |
For connecting the 8100-104 to the LI-8100 for single chamber, long-term measurements. |
| 8150-770 |
1 |
AC Power Supply |
For use with the LI-8150-8 in order to multiplex. |
| 8150-706 |
1 |
DC Power Cable |
For connecting a user-supplied battery with the LI-8150-8 in order to multiplex. |
| 8100-202 |
1 |
Soil Moisture Probe |
For use with the LI-8100 and 8100-103 for survey measurements or 8100-104 for single chamber, long-term measurements. |
| 8100-201 |
1 |
Soil Temperature Probe |
For use with the LI-8100 and 8100-103 for survey measurements only. |
| 8100-203 |
1 |
Soil Temperature Thermistor |
For use with the LI-8100 and 8100-104 for single chamber, long-term measurements. |
| 8150-202 |
4 |
Soil Moisture Probe |
Connects directly to the 8100-104; for use only if you multiplex. |
| 8150-203 |
4 |
Soil Temperature Thermistor |
Connects directly to the 8100-104; for use only if you multiplex. |
| 8150-662 |
1 |
Profiling Kit |
Connects to the LI-8150-08 (includes 4 ports). |
| 8100-664 |
1 |
Trace Gas Sampling Kit |
Sample the same air stream used for CO2 flux for further trace gas analysis. |
| 8150-250 |
5 |
Bev-a-line |
For use with the Profiling kit (250 ft total). |
| 8100-561 |
1 |
Wireless Communications Package |
For use with any possible system configuration. |
| 6400-03 |
3 |
Battery |
Used for the LI-8100 and 8100-103 only. |
| LI-6020 |
1 |
Battery Charger |
Used to charge the 6400-03 batteries. |
| 8100-785 |
1 |
Two-Year Extended Warranty |
Extends the standard one-year warranty for the LI-8100 to a total of three years. |
| 8150-785 |
1 |
Two-Year Extended Warranty |
Extends the standard one-year warranty for the LI-8150-8 to a total of three years. |
| 8100-520 |
1 |
Field Guide |
A CD containing field exercises used for teaching or research. |
A number of upgrades are available as future teaching and research needs change.
- Upgrade the 8 port Multiplexer (LI-8150-8) to a 16 port Multiplexer (LI-8150-16)
- Add more long-term chambers and accessories as needed
- Add the 8100-102 (10cm diameter) survey chamber
- If upgrades and/or additional chambers or any accessories are purchased with this package on the same order, a 10% discount will apply to the entire additional items purchased.
LI-8100TR Package Pricing & Questions
For pricing information or if you have any questions or you need a quote please contact Chris Mantzios, National Sales Manager at 800-447-3574 ext 3754, chris.mantzios@licor.com or Kristin Feese, Technical Sales Associate at 800-447-3576 ext 3882, kristin.feese@licor.com.
 :
|